Basic Info.
After-sales Service
The Standard-Compliant Recovery Rate
Material
Rubber / Plastic
Customized Support
OEM, ODM
Transport Package
10/Pack
Product Description
RayCure AL-N cartridge is based on neutral alumina as
sorbent, used to retain or remove polar compounds. It is a
strong polar adsorbent at pH 7.5.
Features
• Strong polar adsorbent at pH 7.5, neutral surface
• Deactivation treatment, no interactions to process
• More stable than silica-bonded phase in high pH solution
Application
• Malachite green and crystal violet in aquatic products
• Vitamins, antibiotics, aromatic oils, enzymes, glycosides
• Sample pre-treatment of hormones
• Pigments such as Sudan red
• Electron-rich compounds such as heterocycles, aromatic
hydrocarbons and organic amines
Product Specifications
Part number | Description |
RC-204-13802 | SPE cartridge:RayCure GCB,250mg/6mL,30/Pack |
RC-204-13804 | SPE cartridge:RayCure GCB,500mg/6mL,30/Pack |
RC-204-13806 | SPE cartridge:RayCure GCB,250mg/3mL,50/Pack |
RC-204-13807 | SPE cartridge:RayCure GCB,2000mg/12mL,20/Pack |
RC-204-68305 | SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack |
RC-204-16861 | SPE cartridge:RayCure AL-A,100mg/1mL,100/Pack |
RC-204-16862 | SPE cartridge:RayCure AL-A,200mg/3mL,50/Pack |
RC-204-16863 | SPE cartridge:RayCure AL-A,500mg/3mL,50/Pack |
RC-204-16864 | SPE cartridge:RayCure AL-A,500mg/6mL,30/Pack |
RC-204-16865 | SPE cartridge:RayCure AL-A,1000mg/6mL,30/Pack |
RC-204-16866 | SPE cartridge:RayCure AL-A,2000mg/6mL,30/Pack |
RC-204-16867 | SPE cartridge:RayCure AL-A,60mg/3mL,50/Pack |
RC-204-16881 | SPE cartridge:RayCure AL-B,100mg/1mL,100/Pack |
RC-204-16882 | SPE cartridge:RayCure AL-B,200mg/3mL,50/Pack |
RC-204-16883 | SPE cartridge:RayCure AL-B,500mg/3mL,50/Pack |
RC-204-16884 | SPE cartridge:RayCure AL-B,500mg/6mL,30/Pack |
RC-204-16885 | SPE cartridge:RayCure AL-B,1000mg/6mL,30/Pack |
RC-204-16886 | SPE cartridge:RayCure AL-B,2000mg/6mL,30/Pack |
RC-204-16887 | SPE cartridge:RayCure AL-B,2000mg/12mL,20/Pack |
RC-204-16901 | SPE cartridge:RayCure AL-N,100mg/1mL,100/Pack |
RC-204-16902 | SPE cartridge:RayCure AL-N,200mg/3mL,50/Pack |
RC-204-16903 | SPE cartridge:RayCure AL-N,500mg/3mL,50/Pack |
RC-204-16904 | SPE cartridge:RayCure AL-N,500mg/6mL,30/Pack |
RC-204-16904N | SPE cartridge: RayCure AL-N,500mg/6mL,30/Pack,SPE-06D specific |
RC-204-16905 | SPE cartridge:RayCure AL-N,1000mg/6mL,30/Pack |
RC-204-16906 | SPE cartridge:RayCure AL-N,2000mg/6mL,30/Pack |
RC-204-16907 | SPE cartridge:RayCure AL-N,60mg/3ml,50/Pack |
RC-204-16908 | SPE cartridge:RayCure AL-N,1000mg/3mL,50/Pack |
RC-204-16909 | SPE cartridge:RayCure AL-N,20g/60ml,10/Pack |
RC-204-16941 | SPE cartridge:RayCure Florisil ,100mg/1mL,100/Pack |
RC-204-16942 | SPE cartridge:RayCure Florisil ,200mg/3mL,50/Pack |
RC-204-16943 | SPE cartridge:RayCure Florisil ,500mg/3mL,50/Pack |
RC-204-16944 | SPE cartridge:RayCure Florisil ,500mg/6mL,30/Pack |
RC-204-16945 | SPE cartridge:RayCure Florisil ,1g/6mL,60-100Mesh,30/Pack |
RC-204-16947 | SPE cartridge:RayCure Florisil ,500mg/12mL,20/Pack |
RC-204-16948 | SPE cartridge:RayCure Florisil ,1g/12mL,20/Pack |
RC-204-16949 | SPE cartridge:RayCure Florisil ,1g/6mL,100-200Mesh,30/Pack |
RC-204-68305 | SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack |
RC-204-E4301 | SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack |
RC-204-E4301N | SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack,SPE-06D specific |
RC-204-E4302 | SPE cartridge:RayCure Na2SO4,1g/6mL,30/Pack |
HOW DOES SPE COLUMN WORK?
SPE is a conventional and efficient extraction technique, it uses the affinity of solutes dissolved or suspended in mobile phase for stationary phase to separate desired compounds from a mixture. And there are two solid phase extraction mechanisms to obtain target analytes from complex samples, to retain desired compounds in stationary phase or retain impurities in solid phase. Depending on the difference of two mechanisms, SPE procedures could be a bit various.
When sample portion passes through SPE column, undesired impurities are discarded with mobile phase, target compounds are retained in stationary phase, then rinse stationary phase with eluents to collect target compounds. It is the most commonly used purification mechanism of solid phase extraction.
In the opposite, to retain impurities in stationary phase, target compounds and few impurities are collected in mobile phase when sample portion passes through SPE column. Rinse the stationary phase which impurities is retained with solvents to obtain rest of retained target compounds. This mechanism is mostly used to eliminate fat-soluble impurities of ion analysis and analysis of multiple pesticides in fruits and vegetables.
Company Profile
Raykol Group is a leading professional supplier focusing on R&D, design and manufacture for automated laboratory equipment and solutions in the laboratory automation systems market. And we provide pre-sales product selection guide and after-sales technical supports. RayKol's automted lab systems and products are applied to sample preparation process in the area of food safety, environmental science, agriculture, pharmaceuticals and life science.
With knowledgeable scientists and experienced engineers, our R&D team has developed a variety of innovative instruments and solutions dedicated to the modern analytical laboratories.We are committed to provide ONE stop analytical testing solutions corresponding to user requirements with quality and accuracy, but also contribute to human health together.
Headquartered at Xiamen, Fujian China, RayKol group consists of six subcompanies, three research bases and one research institute. Total over 450 employees and 50 external special experts, and we are still growing.
Raykol Patents
Company Culture
Mission
Innovation creates values, Knowledge optimized laboratory
Vision
World-leading manufacturer and supplier for laboratory automation systems and services
Value
Dedication, innovation, motivation, cooperation
Company Certificate
RayKol Group has been certified as SGS Excellent Supplier in China mainland since July 2023.
Address:
Unit 6f, No. 176xinfeng Road, Huizhizone, Torch High-TechZone, Xiamen, Fujian, China
Business Type:
Manufacturer/Factory
Business Range:
Agriculture & Food, Health & Medicine, Instruments & Meters, Light Industry & Daily Use, Metallurgy, Mineral & Energy, Textile
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Raykol Group is a leading professional supplier focusing on R&D, design and manufacture for automated laboratory equipment and solutions in the laboratory automation systems market. And we provide pre-sales product selection guide and after-sales technical supports. RayKol′s automted lab systems and products are applied to sample preparation process in the area of food safety, environmental science, agriculture, pharmaceuticals and life science.
With knowledgeable scientists and experienced engineers, our R&D team has developed a variety of innovative instruments and solutions dedicated to the modern analytical laboratories. We are committed to provide ONE stop analytical testing solutions corresponding to user requirements with quality and accuracy, but also contribute to human health together.
Headquartered at Xiamen, Fujian China, RayKol group consists of six subcompanies, three research bases and one research institute. Total over 450 employees and 50 external special experts, and we are still growing.
Mission
Innovation creates values, Knowledge optimized laboratory
Vision
World-leading manufacturer and supplier for laboratory automation systems and services
Value
Dedication, innovation, motivation, cooperation