MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis

Product Details
Customization: Available
After-sales Service: The Standard-Compliant Recovery Rate
Warranty: 36 Months
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (23)
  • MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
  • MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
  • MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
  • MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
  • MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
  • MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
Find Similar Products
  • Overview
  • Product Specifications
Overview

Basic Info.

Model NO.
RC-204-72860
Reactant State
Solid
Material
Rubber / Plastic
Customized Support
OEM, ODM
Lead Time (Days)
7days
Delivery Terms
Ex-Work
Product Name
MCX
Category
Mixed Strong Anion Exchange Reversed-Phase Column
Transport Package
30/Pack
Specification
60g/6mL
Trademark
RayCure
Origin
China
HS Code
84219990
Production Capacity
10000pieces/Year

Packaging & Delivery

Package Size
15.50cm * 12.50cm * 10.00cm
Package Gross Weight
0.300kg
Lead Time
7 days (1 - 30 Pieces)
To be negotiated ( > 30 Pieces)

Product Description





RayCure MCX is a water-wettable SPE cartridge based on styrene-divinylbenzene polymer containing hydrophilic group and introducing strong cation exchange groups (sulfonic acid groups) as sorbent, perfect for enrichment of weak cation compounds. It is mainly used for pesticide and veterinary drug residues in food, and drugs and their metabolites in biological matrices.
MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
 
Product Specifications
 
Part number Description
RC-204-13802 SPE cartridge:RayCure GCB,250mg/6mL,30/Pack
RC-204-13804 SPE cartridge:RayCure GCB,500mg/6mL,30/Pack
RC-204-13806 SPE cartridge:RayCure GCB,250mg/3mL,50/Pack
RC-204-13807 SPE cartridge:RayCure GCB,2000mg/12mL,20/Pack
RC-204-68305 SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack
RC-204-16861 SPE cartridge:RayCure AL-A,100mg/1mL,100/Pack
RC-204-16862 SPE cartridge:RayCure AL-A,200mg/3mL,50/Pack
RC-204-16863 SPE cartridge:RayCure AL-A,500mg/3mL,50/Pack
RC-204-16864 SPE cartridge:RayCure AL-A,500mg/6mL,30/Pack
RC-204-16865 SPE cartridge:RayCure AL-A,1000mg/6mL,30/Pack
RC-204-16866 SPE cartridge:RayCure AL-A,2000mg/6mL,30/Pack
RC-204-16867 SPE cartridge:RayCure AL-A,60mg/3mL,50/Pack
RC-204-16881 SPE cartridge:RayCure AL-B,100mg/1mL,100/Pack
RC-204-16882 SPE cartridge:RayCure AL-B,200mg/3mL,50/Pack
RC-204-16883 SPE cartridge:RayCure AL-B,500mg/3mL,50/Pack
RC-204-16884 SPE cartridge:RayCure AL-B,500mg/6mL,30/Pack
RC-204-16885 SPE cartridge:RayCure AL-B,1000mg/6mL,30/Pack
RC-204-16886 SPE cartridge:RayCure AL-B,2000mg/6mL,30/Pack
RC-204-16887 SPE cartridge:RayCure AL-B,2000mg/12mL,20/Pack
RC-204-16901 SPE cartridge:RayCure AL-N,100mg/1mL,100/Pack
RC-204-16902 SPE cartridge:RayCure AL-N,200mg/3mL,50/Pack
RC-204-16903 SPE cartridge:RayCure AL-N,500mg/3mL,50/Pack
RC-204-16904 SPE cartridge:RayCure AL-N,500mg/6mL,30/Pack
RC-204-16904N SPE cartridge: RayCure AL-N,500mg/6mL,30/Pack,SPE-06D specific
RC-204-16905 SPE cartridge:RayCure AL-N,1000mg/6mL,30/Pack
RC-204-16906 SPE cartridge:RayCure AL-N,2000mg/6mL,30/Pack
RC-204-16907 SPE cartridge:RayCure AL-N,60mg/3ml,50/Pack
RC-204-16908 SPE cartridge:RayCure AL-N,1000mg/3mL,50/Pack
RC-204-16909 SPE cartridge:RayCure AL-N,20g/60ml,10/Pack
RC-204-16941 SPE cartridge:RayCure Florisil ,100mg/1mL,100/Pack
RC-204-16942 SPE cartridge:RayCure Florisil ,200mg/3mL,50/Pack
RC-204-16943 SPE cartridge:RayCure Florisil ,500mg/3mL,50/Pack
RC-204-16944 SPE cartridge:RayCure Florisil ,500mg/6mL,30/Pack
RC-204-16945 SPE cartridge:RayCure Florisil ,1g/6mL,60-100Mesh,30/Pack
RC-204-16947 SPE cartridge:RayCure Florisil ,500mg/12mL,20/Pack
RC-204-16948 SPE cartridge:RayCure Florisil ,1g/12mL,20/Pack
RC-204-16949 SPE cartridge:RayCure Florisil ,1g/6mL,100-200Mesh,30/Pack
RC-204-68305 SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack
RC-204-E4301 SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack
RC-204-E4301N SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack,SPE-06D specific
RC-204-E4302 SPE cartridge:RayCure Na2SO4,1g/6mL,30/Pack

MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental AnalysisMCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis

MCX 60g/6ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis

Rule I:

The properties of solid phase packing in SPE cartridges should be match to target compounds.

Rule II:

Take the advantage of differences between analytes of interest and interferences

Rule III:

Consider nature of SPE sample matrices, characteristics of analytes and solubility of used solvents

 

Users can select RayCure SPE columns depending on properties of desired analytes and sample matrices as following selection guides.

Target compounds Properties of analytes Corresponding SPE
Solubility Polarity/Ionicity SPE mechanism Sorbent phase
Water soluble Compounds with high/low polarity Non-polar C18
Polymer HLB
Ionic compounds Anion exchange MCX, WCX
Cation exchange MAX, WAX
Soluble in organic solvents Polar compounds Normal phase bonding PSA, NH2
Compounds with neutral polarity Normal phase adsorption Silica, Florisil
Non-polar compounds Reversed phase C18


Based on nature of SPE sample matrices

SPE sample matrices

SPE sample matrices Target compounds Impurities RayCure SPE column
Fruits, vegetables, fruit juice, vegetable juice, fruit wine, herbs Multiple pesticide residues Carbohydrates, pigments, organic acid, phenol RayCure QuEChERS d-SPE kits
RayCure NH2
RayCure PSA
RayCure GCB/NH2
RayCure GCB/PSA
RayCure Florisil
Weak polar pesticides Carbohydrates, pigments, organic acid, phenol RayCure HLB
RayCure C18
Alkali pesticides Carbohydrates, pigments, organic acid, phenol RayCure MCX
RayCure WCX
Acidic pesticides Carbohydrates, pigments, organic acid, phenol RayCure MAX
RayCure WAX
Dairy products, blood, urine, animal tissues Neutral, weak alkali, weak acidic drugs Proteins, fats RayCure HLB
RayCure C18
Alkali drugs Proteins, fats RayCure MCX
RayCure WCX
Acidic drugs Proteins, fats RayCure MAX
RayCure WAX
Soil, wastewater hydrophobic organic pollutants Humic substances RayCure HLB
RayCure C18
Pesticide residues Humic substances RayCure Florisil
Oil and grease Fat-soluble vitamins, phospholipids, aflatoxins Fats RayCure Silica
RayCure NH2
RayCure PSA



HOW DOES SPE COLUMN WORK?

SPE is a conventional and efficient extraction technique, it uses the affinity of solutes dissolved or suspended in mobile phase for stationary phase to separate desired compounds from a mixture. And there are two solid phase extraction mechanisms to obtain target analytes from complex samples, to retain desired compounds in stationary phase or retain impurities in solid phase. Depending on the difference of two mechanisms, SPE procedures could be a bit various. 

 

When sample portion passes through SPE column, undesired impurities are discarded with mobile phase, target compounds are retained in stationary phase, then rinse stationary phase with eluents to collect target compounds. It is the most commonly used purification mechanism of solid phase extraction. 

 

In the opposite, to retain impurities in stationary phase, target compounds and few impurities are collected in mobile phase when sample portion passes through SPE column. Rinse the stationary phase which impurities is retained with solvents to obtain rest of retained target compounds. This mechanism is mostly used to eliminate fat-soluble impurities of ion analysis and analysis of multiple pesticides in fruits and vegetables.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier