Basic Info.
After-sales Service
The Standard-Compliant Recovery Rate
Material
Rubber / Plastic
Customized Support
OEM, ODM
Category
Inorganic-Based Spe Cartridge
Transport Package
30/Pack
Product Description
RayCure GCB cartridge is based on graphitized carbon
with planar structure as sorbent, mainly used to remove
pigments and polar substances from crops. It utilizes
dual action of polarity and the ion exchange solid phase to effectively purify all kinds of sample matrices.
Product Specifications
Part number | Description |
RC-204-13802 | SPE cartridge:RayCure GCB,250mg/6mL,30/Pack |
RC-204-13804 | SPE cartridge:RayCure GCB,500mg/6mL,30/Pack |
RC-204-13806 | SPE cartridge:RayCure GCB,250mg/3mL,50/Pack |
RC-204-13807 | SPE cartridge:RayCure GCB,2000mg/12mL,20/Pack |
RC-204-68305 | SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack |
RC-204-16861 | SPE cartridge:RayCure AL-A,100mg/1mL,100/Pack |
RC-204-16862 | SPE cartridge:RayCure AL-A,200mg/3mL,50/Pack |
RC-204-16863 | SPE cartridge:RayCure AL-A,500mg/3mL,50/Pack |
RC-204-16864 | SPE cartridge:RayCure AL-A,500mg/6mL,30/Pack |
RC-204-16865 | SPE cartridge:RayCure AL-A,1000mg/6mL,30/Pack |
RC-204-16866 | SPE cartridge:RayCure AL-A,2000mg/6mL,30/Pack |
RC-204-16867 | SPE cartridge:RayCure AL-A,60mg/3mL,50/Pack |
RC-204-16881 | SPE cartridge:RayCure AL-B,100mg/1mL,100/Pack |
RC-204-16882 | SPE cartridge:RayCure AL-B,200mg/3mL,50/Pack |
RC-204-16883 | SPE cartridge:RayCure AL-B,500mg/3mL,50/Pack |
RC-204-16884 | SPE cartridge:RayCure AL-B,500mg/6mL,30/Pack |
RC-204-16885 | SPE cartridge:RayCure AL-B,1000mg/6mL,30/Pack |
RC-204-16886 | SPE cartridge:RayCure AL-B,2000mg/6mL,30/Pack |
RC-204-16887 | SPE cartridge:RayCure AL-B,2000mg/12mL,20/Pack |
RC-204-16901 | SPE cartridge:RayCure AL-N,100mg/1mL,100/Pack |
RC-204-16902 | SPE cartridge:RayCure AL-N,200mg/3mL,50/Pack |
RC-204-16903 | SPE cartridge:RayCure AL-N,500mg/3mL,50/Pack |
RC-204-16904 | SPE cartridge:RayCure AL-N,500mg/6mL,30/Pack |
RC-204-16904N | SPE cartridge: RayCure AL-N,500mg/6mL,30/Pack,SPE-06D specific |
RC-204-16905 | SPE cartridge:RayCure AL-N,1000mg/6mL,30/Pack |
RC-204-16906 | SPE cartridge:RayCure AL-N,2000mg/6mL,30/Pack |
RC-204-16907 | SPE cartridge:RayCure AL-N,60mg/3ml,50/Pack |
RC-204-16908 | SPE cartridge:RayCure AL-N,1000mg/3mL,50/Pack |
RC-204-16909 | SPE cartridge:RayCure AL-N,20g/60ml,10/Pack |
RC-204-16941 | SPE cartridge:RayCure Florisil ,100mg/1mL,100/Pack |
RC-204-16942 | SPE cartridge:RayCure Florisil ,200mg/3mL,50/Pack |
RC-204-16943 | SPE cartridge:RayCure Florisil ,500mg/3mL,50/Pack |
RC-204-16944 | SPE cartridge:RayCure Florisil ,500mg/6mL,30/Pack |
RC-204-16945 | SPE cartridge:RayCure Florisil ,1g/6mL,60-100Mesh,30/Pack |
RC-204-16947 | SPE cartridge:RayCure Florisil ,500mg/12mL,20/Pack |
RC-204-16948 | SPE cartridge:RayCure Florisil ,1g/12mL,20/Pack |
RC-204-16949 | SPE cartridge:RayCure Florisil ,1g/6mL,100-200Mesh,30/Pack |
RC-204-68305 | SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack |
RC-204-E4301 | SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack |
RC-204-E4301N | SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack,SPE-06D specific |
RC-204-E4302 | SPE cartridge:RayCure Na2SO4,1g/6mL,30/Pack |
Selection Rule
Rule I:
The properties of solid phase packing in SPE cartridges should be match to target compounds.
Rule II:
Take the advantage of differences between analytes of interest and interferences
Rule III:
Consider nature of SPE sample matrices, characteristics of analytes and solubility of used solvents
Users can select RayCure SPE columns depending on properties of desired analytes and sample matrices as following selection guides.
Target compounds | Properties of analytes | Corresponding SPE |
Solubility | Polarity/Ionicity | SPE mechanism | Sorbent phase |
Water soluble | Compounds with high/low polarity | Non-polar | C18 |
Polymer | HLB |
Ionic compounds | Anion exchange | MCX, WCX |
Cation exchange | MAX, WAX |
Soluble in organic solvents | Polar compounds | Normal phase bonding | PSA, NH2 |
Compounds with neutral polarity | Normal phase adsorption | Silica, Florisil |
Non-polar compounds | Reversed phase | C18 |
Based on nature of SPE sample matrices
SPE sample matrices
SPE sample matrices | Target compounds | Impurities | RayCure SPE column |
Fruits, vegetables, fruit juice, vegetable juice, fruit wine, herbs | Multiple pesticide residues | Carbohydrates, pigments, organic acid, phenol | RayCure QuEChERS d-SPE kits |
RayCure NH2 |
RayCure PSA |
RayCure GCB/NH2 |
RayCure GCB/PSA |
RayCure Florisil |
Weak polar pesticides | Carbohydrates, pigments, organic acid, phenol | RayCure HLB |
RayCure C18 |
Alkali pesticides | Carbohydrates, pigments, organic acid, phenol | RayCure MCX |
RayCure WCX |
Acidic pesticides | Carbohydrates, pigments, organic acid, phenol | RayCure MAX |
RayCure WAX |
Dairy products, blood, urine, animal tissues | Neutral, weak alkali, weak acidic drugs | Proteins, fats | RayCure HLB |
RayCure C18 |
Alkali drugs | Proteins, fats | RayCure MCX |
RayCure WCX |
Acidic drugs | Proteins, fats | RayCure MAX |
RayCure WAX |
Soil, wastewater | hydrophobic organic pollutants | Humic substances | RayCure HLB |
RayCure C18 |
Pesticide residues | Humic substances | RayCure Florisil |
Oil and grease | Fat-soluble vitamins, phospholipids, aflatoxins | Fats | RayCure Silica |
RayCure NH2 |
RayCure PSA |
Company Profile
Raykol Group is a leading professional supplier focusing on R&D, design and manufacture for automated laboratory equipment and solutions in the laboratory automation systems market. And we provide pre-sales product selection guide and after-sales technical supports. RayKol's automted lab systems and products are applied to sample preparation process in the area of food safety, environmental science, agriculture, pharmaceuticals and life science.
With knowledgeable scientists and experienced engineers, our R&D team has developed a variety of innovative instruments and solutions dedicated to the modern analytical laboratories.We are committed to provide ONE stop analytical testing solutions corresponding to user requirements with quality and accuracy, but also contribute to human health together.
Headquartered at Xiamen, Fujian China, RayKol group consists of six subcompanies, three research bases and one research institute. Total over 450 employees and 50 external special experts, and we are still growing.
Raykol Patents
Company Culture
Mission
Innovation creates values, Knowledge optimized laboratory
Vision
World-leading manufacturer and supplier for laboratory automation systems and services
Value
Dedication, innovation, motivation, cooperation
Company Certificate
RayKol Group has been certified as SGS Excellent Supplier in China mainland since July 2023.
HOW DOES SPE COLUMN WORK?
SPE is a conventional and efficient extraction technique, it uses the affinity of solutes dissolved or suspended in mobile phase for stationary phase to separate desired compounds from a mixture. And there are two solid phase extraction mechanisms to obtain target analytes from complex samples, to retain desired compounds in stationary phase or retain impurities in solid phase. Depending on the difference of two mechanisms, SPE procedures could be a bit various.
When sample portion passes through SPE column, undesired impurities are discarded with mobile phase, target compounds are retained in stationary phase, then rinse stationary phase with eluents to collect target compounds. It is the most commonly used purification mechanism of solid phase extraction.
In the opposite, to retain impurities in stationary phase, target compounds and few impurities are collected in mobile phase when sample portion passes through SPE column. Rinse the stationary phase which impurities is retained with solvents to obtain rest of retained target compounds. This mechanism is mostly used to eliminate fat-soluble impurities of ion analysis and analysis of multiple pesticides in fruits and vegetables.
Address:
Unit 6f, No. 176xinfeng Road, Huizhizone, Torch High-TechZone, Xiamen, Fujian, China
Business Type:
Manufacturer/Factory
Business Range:
Agriculture & Food, Health & Medicine, Instruments & Meters, Light Industry & Daily Use, Metallurgy, Mineral & Energy, Textile
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Raykol Group is a leading professional supplier focusing on R&D, design and manufacture for automated laboratory equipment and solutions in the laboratory automation systems market. And we provide pre-sales product selection guide and after-sales technical supports. RayKol′s automted lab systems and products are applied to sample preparation process in the area of food safety, environmental science, agriculture, pharmaceuticals and life science.
With knowledgeable scientists and experienced engineers, our R&D team has developed a variety of innovative instruments and solutions dedicated to the modern analytical laboratories. We are committed to provide ONE stop analytical testing solutions corresponding to user requirements with quality and accuracy, but also contribute to human health together.
Headquartered at Xiamen, Fujian China, RayKol group consists of six subcompanies, three research bases and one research institute. Total over 450 employees and 50 external special experts, and we are still growing.
Mission
Innovation creates values, Knowledge optimized laboratory
Vision
World-leading manufacturer and supplier for laboratory automation systems and services
Value
Dedication, innovation, motivation, cooperation